Calculate the screw according to traditional methods not to mention the calculation of the effective parameters such as the effective radius, effective helical angle. To increase the efficiency of the screw, we can not ignore these factors. Based on the new calculation method of Emeritus Professor Alan W.Robert we decided digiai screw standing problem with the following parameters: A vertical screw conveyor elevator with a forced feeding system is used in an unloading operation. The screw diameter D = 0.5 m, shaft diameter Dc = 0.25m, pitch p = 0.375m, length L = 10m. The conveyor is to elevate coal of bulk density t/m3, N = 80rev/m, fill ratio . Inner diameter shaft Ri = 0.12m
RCMME 2014, 9th & 10th October 2014, HUST, Hanoi, Vietnam
Author:  Ngo Van Quyet , Ta Hong Phong, and  Nguyen Van Cuong
Sao Do University, 24 Thai Hoc Street, Sao Do ward, Chi Linh Town, Hai Duong city, Viet Nam
Email:nvquyettptt@yahoo.com.vn, tahongphong13@yahoo.com, nguyencuongama@gmail.com.
 

Tác giả bài viết: Ngo Van Quyet , Ta Hong Phong, and Nguyen Van Cuong